<< Back To Home

AIR FLOW AND BED NET USE

Saturday, 28th of July 2012 Print
  • AIR FLOW AND BED NET USE

‘Thermal discomfort is a factor limiting bednet use.’

Airflow attenuation and bed net utilization: Observations from Africa and Asia

Lorenz von Seidlein, Ikonomedis Konstantin, Rasmus Bruun, Musa Jawara, Margaret Pinder, Bart GJ Knols and Jakob B Knudsen 

Malaria Journal 2012, 11:200 doi:10.1186/1475-2875-11-200

Published: 15 June 2012

Abstract (provisional)

Background/Methods Qualitative studies suggest that bed nets affect the thermal comfort of users. To understand and reduce this discomfort the effect of bed nets on temperature, humidity, and airflow was measured in rural homes in Asia and Africa, as well as in an experimental wind tunnel. Two investigators with architectural training selected 60 houses in The Gambia, Tanzania, Philippines, and Thailand. Data-loggers were used to measure indoor temperatures in hourly intervals over a 12 months period. In a subgroup of 20 houses airflow, temperature and humidity were measured at five-minute intervals for one night from 21.00 to 6.00 hrs inside and outside of bed nets using sensors and omni-directional thermo-anemometers. An investigator set up a bed net with a mesh size of 220 holes per inch2 in each study household and slept under the bed net to simulate a realistic environment. The attenuation of airflow caused by bed nets of different mesh sizes was also measured in an experimental wind tunnel.

Results

The highest indoor temperatures (49.0 C) were measured in The Gambia. During the hottest months of the year the mean temperature at night (9 pm) was between 33.1 C (The Gambia) and 26.2 C (Thailand). The bed net attenuated the airflow from a minimum of 27% (Philippines) to a maximum of 71% (The Gambia). Overall the bed nets reduced airflow compared to un-attenuated airflow from 9 to 4 cm sec-1or 52% (p < 0.001). In all sites, no statistically significant difference in temperature or humidity was detected between the inside and outside of the bed net. Wind tunnel experiments with 11 different mesh-sized bed nets showed an overall reduction in airflow of 64% (range 55 - 71%) compared to un-attenuated airflow. As expected, airflow decreased with increasing net mesh size. Nets with a mesh of 136 holes inch-2 reduced airflow by 55% (mean; range 51 - 73%). A denser net (200 holes inch-2) attenuated airflow by 59% (mean; range 56 - 74%).

Discussion

Despite concerted efforts to increase the uptake of this intervention in many areas uptake remains poor. Bed nets reduce airflow, but have no influence on temperature and humidity. The discomfort associated with bed nets is likely to be most intolerable during the hottest and most humid period of the year, which frequently coincides with the peak of malaria vector densities and the force of pathogen transmission.

Conclusions

These observations suggest thermal discomfort is a factor limiting bed net use and open a range of architectural possibilities to overcome this limitation.



--
To subscribe or unsubscribe from this list, pls contact kidsurvivalmalaria @gmail.com.

Do not subscribe on behalf of friends or colleagues; forward updates to them for their decision.
 
To subscribe, write from your most permanent E-mail address, not necessarily that of your current employer.
 
To subscribe to all child survival updates, pls write to kidsurvival@gmail.com

These updates are available at www.childsurvival.net


Readers of these malaria updates may also wish to visit the websites http://www.malariaworld.org/  and
http://www.allianceformalariaprevention.com/index.php
 
 

41206708